Installation Enabling USB CDC Host mode.
Configure your scanner to communicate in USB CDC Host mode by scanning the barcode below: USB CDC Host Mode or from page 8-6 of the programming manual. The product manual for the LI4278 can be downloaded from the following link:
LI4278 Product Reference Guide (en) (zebra.com)
If the Windows 10 native CDC driver if it is not automatically installed after scanning the USB CDC Host Mode configuration barcode, use the following procedure:
1. In Device Manager, right-click on the newly detected CDC device and select 'Update Driver Software...'
2. Select 'Browse my computer for driver software' and then choose 'Let me pick from a list of available drivers on my computer'
3. From the list of Common hardware types', select 'Ports (COM & LPT)' and click 'Next'
4. If checked, uncheck the box 'Show compatible hardware'
5. From the 'Manufacturer' list, select 'Microsoft'.
6. From the adjacent 'model' list, select 'USB Serial Device' and click 'Next'
7. After the driver is installed, the assigned COM port will be shown in the device name in the device manager.